InTech

NOV-DEC 2017

Issue link: http://intechdigitalxp.isa.org/i/910561

Contents of this Issue

Navigation

Page 51 of 61

52 INTECH NOVEMBER/DECEMBER 2017 WWW.ISA.ORG A NSI/ISA-18.2, Management of Alarm Systems for the Process In dustries, has found wide use and success in improving the develop- ment, design, installation, and manage- ment of alarm systems across the process industry sectors. At a face-face meeting in late October, the ISA18 committee, which originated the standard and has devel - oped a comprehensive series of ISA techni- cal reports to support it, established a plan to further advance the understanding and application of the world's first consensus standard on alarm management. ANSI/ISA-18.2 changed the world of alarm management when first published in 2009 with the introduction of activi- ties grouped into the alarm management life cycle. An IEC version, IEC 62682, was published in late 2014, led by ISA18 co- chairs Donald Dunn of Allied Reliability Group as the IEC convenor and Nicholas Sands of DuPont as secretary/editor. It added improvements such as the elimi- nation of country-centric criteria. The ISA18 committee, drawing on knowledge gained from six years of use across indus- try, then used the IEC version as a start- ing point for preparing the current 2016 ANSI/ISA version of the standard. As decided at the October meeting, Dunn and Sands will once more lead an IEC team in updating IEC 62682 based on the ANSI/ISA 2016 revision. At the same time, ISA18 will begin the process of updating its series of supporting technical reports, which include: n ISA-TR18.2.2, Alarm Identification and Rationalization , addresses alarm identification and rationalization for facilities in the process industries for purposes such as improving safety, en- vironmental protection, product qual- ity, equipment protection, and plant productivity. The methods de scribed are applicable to batch and discrete processes as well as continuous pro - cesses. Identification and rationaliza- tion cover the processes to determine the possible need for or a change to an alarm; to systematically compare alarms to the alarm philosophy; and to determine the alarm set point, con - sequence, operator action, priority, and class. n ISA–TR18.2.3, Basic Alarm Design, gives guidance on implementing the practices set forth in ISA-18.2. Follow- ing the life-cycle model of ISA-18.2, the document assumes that alarms to be addressed in basic alarm design have completed rationalization, where attributes such as alarm set point and priority have been defined. n ISA-TR18.2.4, Enhanced and Advanced Alarm Methods, helps users evaluate when to use enhanced and advanced alarming m ethods, what benefits they can achieve, and what challenges and costs to expect. Per ISA-18.2, en - hanced and advanced alarm methods typically go beyond the basic methods and techniques that are usually, or at least initially, applied. Although sig - nificant improvement in alarm system function and performance can usu - ally be made by following the basic alarming methods and principles, in some cases they may not be sufficient to achieve the goals for performance and operator guidance stated in the alarm philosophy. n ISA-TR18.2.5, Alarm System Monitor- ing, Assessment, and Auditing , pro- vides guidance on the use of alarm system analysis for both ongoing monitoring and periodic performance assessment. Monitoring, assessment, and audit are essential to achieving and maintaining the performance ob jectives of the alarm system. These activities can identify improvement opportunities in the other life-cycle stages, such as philosophy, rationaliza- tion, detailed design, implementation, operation, maintenance, and manage- ment of change. n ISA-TR18.2.6, Alarm Systems for Batch and Discrete Processes, covers the ap - plication of alarm management prin- ciples in ISA-18.2 to batch and discrete processes. The general principles and techniques described are intended for use in the life-cycle management of an alarm system based on programmable electronic controller and computer- based human-machine interface tech - nology. Following the guidance will help to identify and address alarm spec - ification, design, implementation, and management opportunities that are im - portant to batch and discrete processes. It will also help minimize the generation of nuisance alarms that could compli - cate and frustrate an operator's aware- ness, understanding, and response to abnormal situations. n ISA-TR18.2.7, Alarm Management When Utilizing Packaged Systems, gives guidance on how to integrate packaged systems into a basic pro - cess control system–based centralized alarm system. The scope includes dis - cussing various issues that can arise when ISA-18.2 work processes are applied to facilities where packaged systems are used, and providing guid - ance on how to successfully apply ISA- 18.2 in these situations. An additional ISA18 technical report will be published in early 2018. ISA- TR18.2.1, Alarm Philosophy, will provide guidance on how to implement the recommendations and requirements de- scribed in the "Alarm Philosophy" clause of the standard. It will outline potential approaches and give specific examples that can be included in an alarm phi- losophy to properly manage the identi- fication, rationalization, detailed design, implementation, operations, mainte- nance, monitoring and assessment, management of change, and audit life- cycle steps. For information on viewing or obtain- ing ANSI/ISA-18.2-2016 and the sup- porting technical reports, visit www. isa.org/findstandards. For information on ISA18, contact Charley Robinson, crobinson@isa.org. n ISA18 charts updates to ISA/IEC alarm management standard and technical reports New Benchmarks & Metrics | standards

Articles in this issue

Links on this page

Archives of this issue

view archives of InTech - NOV-DEC 2017